Flow-type magnetic separator MF 80/1-UP-P6-N-6-80-N-P

Doprava nad 1000 Kč ZDARMA

  • Online only
Before ordering a product, read the Safety and Handling Conditions, please.

52220
8595133958943
In Stock
We'll send on Tuesday
Last items in stock
€4,782.61 Tax excluded
In Stock
We'll send on Tuesday
Last items in stock

Data sheet

Material Stainless steel DIN 1.4301, EN 10088, ČSN 17240, AISI 304, AKV 7 - non-stabilized austenitic nickel-chromium steel (X5CrNi 18-10)
Surface treatment Sandblasting
Number of magnetic bars 4
Total weight 31,5 kg
Magnetic core weight 16,7 kg
Magnet temperature resistance 80 °C
Input/Output Pipe inner diameter: 80 mm (3 5 ⁄32 in)
Sealing NBR – PERBUNAN
Number of casings Single casing
Maximum pressure PS 6 bar
Product state New
Design UP
Magnetic core induction 17000 Gs
Magnetic casing induction 12200 Gs
Shear force at the core 129 N
Casing tearing force 106 N
Magnet type Neodymium (NdFeB)
Replaceable tubes ANO
Connection Připojení - 2x plochá přivařovací příruba; EN 1092-1, typ 01, DN 80, PN 16; materiál: 1.4301

Additional description

The equipment is designed to separate metallic impurities from media that are not hazardous per Article 13 of Directive 2014/68/EU (PED) - Media group 2. These magnetic flow separators do not fall under any category of pressure equipment per 2014/68/EU (Article 4, para. 3). For more information, visit: www.magneticke-separatory.cz (opens in a new window)

For more information, visit:  www.magnetic-separators.info (opens in a new window)

 TEST METHOD

Magnetic Induction Measurement Procedure

The measurement is performed using a standard gauss meter at the point with the highest design magnetic induction - in the position of the pole pieces, or in the lowest point of the magnetic circuit. The test is repeated 3 times in different locations of the magnetic circuit; then the average magnetic induction is calculated.

Tearing force measurement procedure

This force is measured using a polished steel measurement standard with a diameter of 10 mm and a height of 20 mm. The measurement is performed at the point with the highest design magnetic induction - in the position of the pole pieces, or in the lowest point of the magnetic circuit. The force at which the standard is separated is recorded. The test is repeated 3 times and then the average tearing force is calculated.

For your information, this value is 10 N = approx. 1 kg.

The resulting tearing force depends on a range of factors, e.g. on the dimensions of the measurement standard, the air gap between the standard and the tested magnetic circuit, the measurement standard's surface finish, etc.

The reported tear force values for some products were measured under ideal conditions given by the test environment. However, these values may vary depending on the specific type of environment where, for example, operating conditions and subsequent wear may affect the effectiveness of the product. However, measurements have not been made for all products and in such cases are only an estimate or internal auxiliary calculation by the vendor. The values quoted are therefore to be considered as indicative and the Seller declares that they are not a description of the goods in terms of the agreed characteristics in the sales contract on the basis of Article 6(a) of Directive (EU) 2019/771 of the European Parliament and of the Council of 20 May 2019 on certain aspects of contracts for the sale of goods, amending Regulation (EU) 2017/2394 and Directive 2009/22/EC and repealing Directive 1999/44/EC. In order to determine the exact value of the tear force in a specific case, it is necessary to carry out the actual measurement. In case the detected values of the breakaway force are not sufficient for you, as they do not correspond to the stated values, you can take advantage of the guaranteed return option within 30 days under the conditions stated here: https://magsy.shop/goods-returning/ and purchase a stronger magnet. These 30 days are just for testing the goods, after which the seller can refuse the return.